Send Message
Contact Us

Contact Person : Andrea

Phone Number : 0086-371-60547601

whatsapp : +8613598873045

Free call

SHD-GC Power 3 Conductor Power Cable , Special Power Cable Easy Handling

Minimum Order Quantity : 1000meters Packaging Details : roll drum
Delivery Time : 20days after payment Payment Terms : L/C, T/T
Place of Origin: Henan Brand Name: CN CABLE
Certification: CE Model Number: SHD-GC power cable

Detail Information

Conductor: 6 AWG Thru 500 Kcmil Coated Annealed Copper, Bunched Wires, Rope-lay-stranded Per Insulation: Ethylene Propylene Rubber (EPR) Insulation
Insulation Shield:: A Flexible Coated Copper/textile Braid Shield Isapplied Over Non-conducting Overlapped Tape Ground-Check Conductor:: Annealed Copper
Grounding Conductors: Coated Copper, Rope-lay-stranded Per ASTM B172 Two Conductors In Contact With The Flexible Copper Braid Shield Jacket:: Reinforced, Two-layer, Extra-heavy-duty, Leadcured Chlorinated Polyethylene (CPE)
High Light:

copper welding cable

,

special power cable

Product Description

SHD-GC Power, Shielded Round Portable w/Ground-Check, EPR/CPE 2000 Volts, 90˚C, Three Conductor power cable

 

Product Construction
Conductor:
6 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
Insulation:
Ethylene Propylene Rubber (EPR) insulation
Insulation Shield:
A flexible coated copper/textile braid shield isapplied over non-conducting overlapped tape
Ground-Check Conductor:
Annealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene
Grounding Conductors:
Coated copper, rope-lay-stranded per ASTM B172 Two conductors in contact with the flexible copper braid shield
Jacket:
Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)
Options:
Colored jackets are available
TPU (Thermoplastic Polyurethane) jacket
Applications:
• Designed for use as trailing cables on AC mining
equipment:
Where a ground-check conductor is required for fail-safe monitoring
With Bretby-type cable handling devices on long wall shearers
- Where induced voltages in the grounding system will not produce a hazard
- On low- and medium-voltage AC circuits where shielding is desired or required
Features:
• Flexible insulation shield provides shock hazard
protection
• Excellent heat, moisture, steam, oil, chemical and radiation resistance
Features (cont’d):
• Flexible for easy handling
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures
Compliances:
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection
Packaging:
• Material cut to length and shipped on nonreturnable reels

 

SHD-GC Power 3 Conductor Power Cable , Special Power Cable Easy Handling 0

 

NO. OF
COND.
COND.
SIZE
(AWG/
kcmil)
COND.
STRAND
NOMINAL
INSULATION
THICKNESS
GRD.
COND.
SIZE
(AWG)
GRD-CHECK
COND. SIZE
(AWG)
NOMINAL
JACKET
THICKNESS
NOMINAL
CABLE
0.D.
COPPER
WEIGHT
NET
WEIGHT
AMPACITY
INCHES mm INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km
3 6 133 0.070 1.8 10 10 0.155 3.9 1.29 32.8 502 748 1130 1682 93
3 4 259 0.070 1.8 8 10 0.155 3.9 1.40 35.6 678 1009 1460 2173 122
3 3 259 0.070 1.8 7 10 0.170 4.3 1.51 38.3 831 1237 1680 2500 140
3 2 259 0.070 1.8 6 8 0.170 4.3 1.59 40.4 1007 1499 1990 2961 159
3 1 259 0.080 2.0 5 8 0.190 4.8 1.76 44.7 1228 1828 2385 3549 184
3 1/0 259 0.080 2.0 4 8 0.190 4.8 1.86 47.2 1485 2210 2765 4115 211
3 2/0 329 0.080 2.0 3 8 0.205 5.2 2.00 50.8 1832 2726 3255 4844 243
3 3/0 413 0.080 2.0 2 8 0.205 5.2 2.13 54.1 2249 3347 3890 5789 279
3 4/0 532 0.080 2.0 1 8 0.220 5.6 2.31 58.7 2854 4248 4720 7024 321
3 250 608 0.095 2.4 1/0 6 0.220 5.6 2.51 63.8 3325 4949 5460 8125 355
3 300 741 0.095 2.4 1/0 6 0.235 6.0 2.68 68.1 3946 5873 6395 9517 398
3 350 851 0.095 2.4 2/0 6 0.235 6.4 2.81 71.4 4493 6686 7280 10834 435
3 500 1221 0.095 2.4 4/0 6 0.265 6.7 3.19 81.0 6641 9883 9820 14614 536
 

 