Send Message
Contact Us

Contact Person : Andrea

Phone Number : 0086-371-60547601

whatsapp : +8613598873045

Free call

XLPE BS 5467 AWA Armoured Power Cable Four Core 600/1000v

Minimum Order Quantity : 1000meter
Place of Origin: Henan, China Brand Name: CN CABLE
Certification: BS Model Number: YJV72

Detail Information

Name: AWA Armoured Power Cable Rated Voltage: 600/1000v
Number Of Core: Single Insulation: XLPE Insulation
Bedding: PVC Bedding Armour: AWA
Sheath: PVC
Highlight:

XLPE awa Armoured Power Cable

,

BS 5467 Armoured Power Cable

,

BS 5467 Armoured PVC cable

Product Description

XLPE BS 5467 AWA Armoured Power Cable Four Core 600/1000v

 

 

APPLICATION

 

AWA Armoured Power Cable for power plant, household electrical appliance, instrument, and telecommunication equipment.

 

CONSTRUCTION
Conductor
Class 2 stranded copper conductor according to
BS EN 60228 (previously BS 6360)
Insulation
XLPE (Cross-Linked Polyethylene)
Bedding
PVC (Polyvinyl Chloride)
Armour
AWA (Aluminium Wire Armour)
Sheath
PVC (Polyvinyl Chloride)

CHARACTERISTICS
Voltage Rating (Uo/U)
600/1000V
Temperature Rating
Fixed: -25°C to +90°C
Minimum Bending Radius
25mm2 and above - Fixed: 8 x overall diameter
Core Identification
1 core: Brown or Blue
Sheath Colour
Black

 

DIMENSIONS
BS5467 XLPE/PVC/AWA/PVC (Copper)

NO. OF
CORES
NOMINAL CROSS
SECTIONAL AREA
mm²
NOMINAL
THICKNESS OF
INSULATION
mm
NOMINAL OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
kg/km
Under
Armour
Overall
1
1
1
1
1
1
1
1
1
1
1
1
1
50
70
95
120
150
185
240
300
400
500
630
800
1000
1
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2
2.2
2.4
2.6
2.8
12.7
14.7
16.6
18.5
20.8
23.2
26
28.6
32.4
36
40
45.6
50.6
17.5
20.2
22.3
24.2
27.4
30
32.8
35.6
40.5
44.2
48.8
55.4
60.6
800
960
1240
1510
1900
2320
2930
3580
4600
5770
7250
9381
11540

 

CONDUCTORS
Class 2 Stranded Conductors for Single Core and Multi-Core Cables

NOMINAL CROSS
SECTIONAL AREA
mm²
MINIMUM NO. OF WIRES IN CONDUCTOR MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
Circular Circular Compacted Shaped Annealed Copper Conductor
CU AL CU AL CU AL Plain Wires
ohms/km
50
70
95
120
150
185
240
300
400
630
800
1000
19
19
19
37
37
37
37
61
61
91
91
91
19
19
19
37
37
37
37
61
61
91
91
91
6
12
15
18
18
30
34
34
53
53
53
53
6
12
15
15
15
30
30
30
53
53
53
53
6
12
15
18
18
30
34
34
53
53
-
-

6
12
15
15
15
30
30
30
53
53
-

-

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.047
0.0283
0.0.221
0.0176

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL CHARACTERISTICS XLPE/PVC/AWA/PVC
Current Carrying Capacity

NOMINAL CROSS
SECTIONAL AREA
mm²
REFERENCE METHOD C
(CLIPPED DIRECT)
REFERENCE METHOD F
(IN FREE AIR OR ON A PERFORATED CABLE TRAY, HORIZONTAL OR VERTICAL)
TOUCHING TOUCHING SPACED BY ONE CABLE DIAMETER
2 Cables
Single-Phase
AC or DC
Flat
Amps
3 or 4 Cables
Three-Phase
AC Flat
Amps
2 Cables
Single-Phase
AC or DC
Flat
Amps
3 Cables
Three-Phase
AC Flat
Amps
3 Cables
Three-Phase
AC Trefoil
Amps
2 Cables DC
Amps
2 Cables
Single-Phase AC
Amps
3 or 4 Cables
Three-Phase AC
Amps
Horizontal Vertical Horizontal Vertical Horizontal Vertical
50
70
95
120
150
185
240
300
400
500
630
800
1000
237
303
367
425
488
557
656
755
853
962
1082
1170
1261
220
277
333
383
437
496
579
662
717
791
861
904
961
253
322
389
449
516
587
689
792
899
1016
1146
1246
1345
232
293
352
405
462
524
612
700
767
851
935
987
1055
222
285
346
402
463
529
625
720
815
918
1027
1119
1214
284
356
446
519
600
688
815
943
1137
1314
1528
1809
2100
270
349
426
497
575
660
782
906
1094
1266
1474
1744
2026
282
357
436
504
566
643
749
842
929
1032
1139
1204
1289
266
337
412
477
539
614
714
805
889
989
1092
1155
1238
288
358
425
485
549
618
715
810
848
923
992
1042
1110
266
331
393
449
510
574
666
755
797
871
940
978
1041

 

Voltage Drop

NOMINAL

CROSS

ECTIONAL

AREA

mm²

TWO

CORE

CABLE

DC

REFERENCE METHOD C & F

 

(CLIPPED DIRECT, ON TRAY OR IN FREE AIR)

2 Cables Single-Phase AC

 

mV/A/m

3 or 4 Cables Three-Phase AC

 

mV/A/m

Touching Spaced* Trefoil and Touching Flat and Touching Flat and Spaced*
r x z r x z r x z r x z r x z

50

70

95

120

150

185

240

300

400

500

630

800

1000

0.980

0.670

0.490

0.390

0.310

0.250

0.195

0.155

0.115

0.093

0.073

0.056

0.045

0.990

0.680

0.510

0.410

0.330

0.270

0.210

0.170

0.145

0.125

0.105

0.090

0.092

0.210

0.200

0.195

0.190

0.185

0.185

0.180

0.175

0.170

0.170

0.165

0.160

0.155

1.000

0.710

0.550

0.450

0.380

0.330

0.280

0.250

0.220

0.210

0.195

0.190

0.180

0.980

0.690

0.530

0.430

0.360

0.300

0.240

0.195

0.180

0.165

0.150

0.145

0.140

0.29

0.29

0.28

0.27

0.27

0.26

0.26

0.25

0.24

0.24

0.23

0.23

0.21

1.00

0.75

0.60

0.51

0.45

0.40

0.35

0.32

0.30

0.29

0.27

0.27

0.25

0.860

0.590

0.440

0.350

0.290

0.230

0.180

0.145

0.125

0.105

0.092

0.086

0.080

0.180

0.170

0.170

0.165

0.160

0.160

0.155

0.150

0.150

0.145

0.145

0.140

0.135

0.870

0.620

0.470

0.390

0.330

0.280

0.240

0.210

0.195

0.180

0.170

0.165

0.155

0.840

0.600

0.460

0.380

0.310

0.260

0.210

0.170

0.160

0.145

0.135

0.130

0.125

0.250

0.250

0.240

0.240

0.230

0.230

0.220

0.220

0.210

0.200

0.195

0.180

0.170

0.88

0.65

0.52

0.44

0.39

0.34

0.30

0.28

0.27

0.25

0.24

0.23

0.21

0.840

0.620

0.490

0.410

0.340

0.290

0.240

0.200

0.200

0.190

0.175

0.175

0.165

0.330

0.320

0.310

0.300

0.290

0.290

0.280

0.270

0.270

0.240

0.230

0.195

0.180

0.90

0.70

0.58

0.51

0.45

0.41

0.37

0.34

0.33

0.31

0.29

0.26

0.24

 

You Might Be Into These
Get in touch with us

Enter Your Message

andrea@cncablegroup.com
+8613598873045
yxcuicui
yxandrea
0086-371-60547601