Black Concentric Armoured Cable 16mm 3 Core 6/3 AWG With PVC Or XLPE Insulation
Contact Person : Andrea
Phone Number : 0086-371-60547601
whatsapp : +8613598873045
Detail Information |
|||
Conductor Material: | Copper | Insulation: | XLPE |
---|---|---|---|
Outer Sheath: | XLPE | Rated Voltage: | 0.6/1KV |
Certificate: | ISO9001/ISO14001 | Standard: | ASTM, IEC, BS,etc. |
Product Name: | 0.6/1KV Aerial Concentric Service Cable 1x16/16mm2 | ||
High Light: | awg power cable,16mm split concentric cable |
Product Description
Application:
The concentric cable is used as electric service entrance from the power distribution network until the meter panel (especially where it is required to prevent "black" losses or electric power robbery), and as feeder cable from the meters panel until the panel or general distribution panel, just as it is specified in the National Electrical Code.
This type of conductor can be used in dry and wet places, directly buried or outdoors; its maximum temperature of operation is 90 ºC and its voltage of service for all the applications is 600 V.
Applicable Standard:
We can produce according to standard ASTM, IEC, BS,etc
Characters:
1.Rated voltage: 0.6/1KV
2.Cable core number: 1Core , 2Core,3Core , 4Core , 5Core , 3+1Core(3.5Core) , 3+2 Core , 4+1Core , etc.
3.Max. Conductor long time operating temp. is 70℃ for PVC Insulation and 90℃ for XLPE Insulation
In short circuit, max. Temp. is 160℃ for PVC Insulation and 250℃ for XLPE Insulation.
Construction:
Concentric electrical cable Conductor
Plain copper or aluminum conductors, IEC 60228, solid or stranded versions, conductor types
10-16 mm² round, solid conductors .
10-25 mm², stranded conductor.
35-240 mm², sector shaped conductor, stranded
Conductor Construction | ||||
Conductor Size | Min Stranding No. | Nominal Diameter | Max. D.C. Resistance at 20℃ | |
AWG/ kcmil | mm2 | mm | mm | Ω/KM |
3 | 26.7 | 6 | 6.05 | 0.68509 |
2 | 33.6 | 6 | 6.81 | 0.54357 |
1 | 42.4 | 7 | 7.59 | 0.43099 |
1/0 | 53.5 | 7 | 8.53 | 0.34094 |
2/0 | 67.4 | 12 | 9.55 | 0.27082 |
3/0 | 85 | 15 | 10.7 | 0.21453 |
4/0 | 107 | 17 | 12.1 | 0.16854 |
250 | 127 | 18 | 13.2 | 0.14409 |
300 | 152 | 18 | 14.5 | 0.12029 |
350 | 177 | 24 | 15.6 | 0.10292 |
400 | 203 | 24 | 16.7 | 0.08909 |
450 | 228 | 30 | 17.8 | 0.07912 |
500 | 253 | 30 | 18.7 | 0.0714 |
550 | 279 | 34 | 19.7 | 0.06561 |
600 | 304 | 34 | 20.7 | 0.06015 |
700 | 355 | 34 | 22.3 | 0.05114 |
750 | 380 | 53 | 23.1 | 0.0476 |
800 | 405 | 53 | 23.8 | 0.04471 |
900 | 456 | 53 | 25.4 | 0.03956 |
1000 | 507 | 53 | 26.9 | 0.0357 |
Insulation, Metallic shield Dimension | |||||
Rated Circuit Voltage, Phase-to-Phase | Conductor Size | XLPE/TRXLPE Insulation Nominal Thickness | Metal Screen | ||
100 Percent Level | 133 Percent Level | 173 Percent Level | Copper Tape | ||
V | AWG/kcmil | mm | mm | mm | mm |
2001-5000 | 8-1000 | 2.3 | 2.3 | 3.6 | 0.06 |
1001-3000 | 3.6 | 3.6 | 3.6 | 0.06 | |
5001-8000 | 6-1000 | 2.9 | 3.6 | 4.4 | 0.06 |
1001-3000 | 4.4 | 4.4 | 5.6 | 0.06 | |
8001-15000 | 2-1000 | 4.4 | 5.6 | 6.6 | 0.06 |
1001-3000 | 5.6 | 5.6 | 6.6 | 0.06 | |
15001-25000 | 1-3000 | 6.6 | 8.1 | 10.7 | 0.06 |
25001-28000 | 1-3000 | 7.1 | 8.8 | 11.3 | 0.06 |
28001-35000 | 1/0-3000 | 8.8 | 10.7 | 14.7 | 0.06 |
35001-46000 | 4/0-3000 | 11.3 | 14.7 | 19.1 | 0.06 |
Concentric Neutral Wire Size | |||
AWG Size | Nominal Diameter | Nominal Area | |
mils | mm | (kcmil) | |
16 | 50.8 | 1.29 | 2.58 |
14 | 64.1 | 1.63 | 4.11 |
12 | 80.8 | 2.05 | 6.53 |
10 | 101.9 | 2.59 | 10.38 |
9 | 114.4 | 2.91 | 13.09 |
8 | 128.5 | 3.26 | 16.51 |
Full Neutral Concentric Copper Conductor | ||||||
Conductor Size AWG/kcmil | Concentric Conductor Minimum Number of Wires | |||||
Copper | Aluminum | 16AWG | 14AWG | 12AWG | 10AWG | 9AWG |
… | 4 | 10* | 6 | … | … | … |
4 | 2 | 16* | 10 | … | … | … |
3 | 1 | 20* | 13 | … | … | … |
2 | 1/0 | 26* | 16 | 10* | … | … |
1 | 2/0 | … | 20* | 13 | … | … |
1/0 | 3/0 | … | 25* | 16 | 10* | … |
2/0 | 4/0 | … | 32* | 20* | 13 | 10* |
3/0 | 250 | … | … | 25* | 16 | 13* |
4/0 | 350 | … | … | 32* | 20* | 16 |
One-third Neutral Concentric Copper Conductor | |||||||
Conductor Size | Concentric Conductor Minimum Number of Wires | ||||||
AWG/kcmil | |||||||
Copper | Aluminum | 16AWG | 14AWG | 12AWG | 10AWG | 9AWG | 8AWG |
2 | 1/0 | 9 | 6 | … | … | … | … |
1 | 2/0 | 11 | 7 | … | … | … | … |
1/0 | 3/0 | 14 | 9 | 6* | … | … | … |
4/0 | 17 | 11 | 7* | … | … | … | |
2/0 | 18 | 11 | 7* | … | … | … | |
250 | 20 | 13 | 8* | … | … | … | |
3/0 | 22 | 14 | 9* | 6* | … | … | |
4/0 | 350 | 28* | 18 | 11* | 7* | 6* | … |
250 | … | 21 | 13* | 9* | 7* | … | |
500 | … | 25* | 16 | 10* | 8* | 7* | |
350 | … | 29* | 18 | 12* | 9* | 8* | |
600 | … | 30* | 19 | 12* | 10* | 8* | |
750 | … | … | 24 | 15* | 12* | 10* | |
500 | … | … | 26* | 17 | 13* | 10* | |
600 | 1000 | … | … | 31* | 20 | 16* | 13* |
650 | … | … | 34* | 21 | 17* | 14* | |
750 | 1250 | … | … | … | 25* | 20 | 16* |
1500 | … | … | … | 30* | 24 | 19* | |
1000 | … | … | … | 32* | 26* | 21 |
Thickness of bedding and size of armor wire | ||
Calculated Dia. of cable under bedding | Min. thickness of bedding | Nominal size of armor wire |
mm | mm | mm |
0-19.05 | 1.14 | 2.11 |
19.08-25.40 | 1.65 | 2.77 |
25.43-43.18 | 2.03 | 3.4 |
43.21-63.50 | 2.03 | 4.19 |
63.53 & larger | 2.41 | 5.16 |
Click for more information
Q1: Are you a manufacturer or a trade company?
A: We are cable manufacturer with 15 years production experience and more than 10 years export experience.
Q2: What`s your export business type / customer groups?
A: Our business includes: Retail, wholesale, government project supply, private engineering supply, international bidding, customer requirements production, OEM , etc. And our customers are : Retailers, Wholesalers, Electric Power Companies, Oil companies, EPC companies, Electrical equipment manufacturers, Factories, Agents, Brokers , etc. No matter which field you are in , if you need cables , just contact us !
Q3: I do not know how to choose what I need. / I have not found the cable type and size I need on this page.
A: Please do not worry. Contact us and send us your requirements, we will help you to choose correct cable you need. If you have below information is better: Cable voltage, conductor material, Insulation and Outer sheath material, armor type. Otherwise you can provide us the cable installation environment, application requirements, etc.
Q4: When can I get the price ?
A: Normally you can get our feedback within 24 hours upon we get your inquiries. As soon as necessary product information is confirmed, our quotation will reach you within 24 hours. For large project and multi-items more than 50 items, we need 3-5 days more.
Q5: What’s your MOQ?/ How long is your delivery time?
A: MOQ & Delivery time both according to different product, product size, production construction. Welcome to contact us for further communication. Anyway, we will try our best to support you!
Q6: What’s your trade term and payment term?
A: Mostly used trade term is EXW, FOB , CFR/CNF, CIF. Payment term varies from different contract value and commercial clauses. Normally 30% TT advance payment is required, the balance payment by TT / LC .
Q7: What`s your quality guarantee and period.
A: We guarantee that all of our products are free from defects. We will take back any product that does not meet the agreed quality by both parties. Usually the guarantee period is 18 months after shipment and 12 months after installation, which is earlier .
Q8: Does your price include destination custom clearance , import tax , installation service ?
A: Sorry, currently we only supply cables and provide shipping service in China. Other services should be re-quoted and negotiated by both parties.
Enter Your Message