15KV 133% TS Copper Special Cables Armor X Cable XLPE Insulation
Contact Person : Andrea
Phone Number : 0086-371-60547601
whatsapp : +8613598873045
Detail Information |
|||
Conductor:: | 1 AWG Thru 500 Kcmil Coated Annealed Copper, Bunched Wires, | Insulation:: | Ethylene Propylene Rubber (EPR) Insulation |
---|---|---|---|
Insulation Shield: | A Flexible Coated Copper/textile Braid Shield Is Applied Over A Non-conducting Overlapped Tape | Ground-Check Conductor: | Coated Copper, Specially Stranded To Provide Extensibility Without Sustaining Tensile Load, Thereby Providing Maximum Resistance To Flex Fatigue • Insulated With High-strength Polypropylene And Placed In The Center Interstice |
Grounding Conductors:: | Three Coated Copper | Jacket: | Reinforced, Two-layer, Extra-heavy-duty, Leadcured Chlorinated Polyethylene (CPE) |
High Light: | copper welding cable,special power cable |
Product Description
SHD-CGC Power, Shielded Round Portable w/Extensible Ground-Check, EPR/CPE 2000 Volts, 90˚C, Three Conductor power cable
Product Construction
Conductor:
• 1 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
Insulation:
• Ethylene Propylene Rubber (EPR) insulation
Insulation Shield:
• A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape
Ground-Check Conductor:
• Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue
• Insulated with high-strength polypropylene and placed in the center interstice
Grounding Conductors:
• Three coated copper, rope-lay-stranded per ASTM B172 in contact with the flexible braid shield
Jacket:
• Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)
Options:
• Colored jackets are available
• TPU (Thermoplastic Polyurethane) jacket
• Anamaxx® jacket
Applications:
• Designed for use as a trailing cable on AC mining equipment:
- Where maximum safety is mandatory, including underground mining machines where induced voltages in an unbalanced grounding
system could be hazardous
- On low- and medium-voltage AC circuits where shielding is desired or required
Features:
• Flexible insulation shield provides shock hazard protection
• Symmetrical grounding system does not produce induced voltages when operating in a balanced 3-phase system
• Excellent heat, moisture, steam, oil, chemical and radiation resistance
Features (cont’d):
• Flexible for easy handling
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage—the cause of most portable cable failures
Compliances:
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection
Packaging:
• Material cut to length and shipped on nonreturnable reels
NO. OF COND. |
COND. SIZE (AWG/ kcmil) |
COND. STRAND |
NOMINAL INSULATION THICKNESS |
GRD. COND. SIZE (AWG) |
GRD-CHECK COND. SIZE (AWG) |
NOMINAL JACKET THICKNESS |
NOMINAL CABLE 0.D. |
COPPER WEIGHT |
NET WEIGHT |
AMPACITY | ||||||
INCHES | mm | INCHES | mm | INCHES | mm | LBS/1000 FT | kg/km | LBS/1000 FT | kg/km | |||||||
3 | 1 | 259 | 0.080 | 2.0 | 7 | 16 | 0.190 | 4.8 | 1.85 | 47.0 | 1196 | 1780 | 2450 | 3645 | 184 | |
3 | 1/0 | 259 | 0.080 | 2.0 | 6 | 16 | 0.190 | 4.8 | 1.95 | 49.5 | 1469 | 2186 | 2779 | 4129 | 211 | |
3 | 2/0 | 329 | 0.080 | 2.0 | 5 | 16 | 0.205 | 5.2 | 2.09 | 53.1 | 1819 | 2708 | 3310 | 4925 | 243 | |
3 | 3/0 | 413 | 0.080 | 2.0 | 4 | 16 | 0.205 | 5.2 | 2.21 | 56.1 | 2237 | 3330 | 3950 | 5877 | 279 | |
3 | 4/0 | 532 | 0.080 | 2.0 | 3 | 16 | 0.220 | 5.6 | 2.36 | 59.9 | 2845 | 4233 | 4630 | 6889 | 321 | |
3 | 250 | 608 | 0.095 | 2.4 | 2 | 16 | 0.235 | 6.0 | 2.51 | 63.8 | 3290 | 4896 | 5440 | 8096 | 355 | |
3 | 300 | 741 | 0.095 | 2.4 | 1 | 16 | 0.235 | 6.0 | 2.68 | 68.1 | 4002 | 5956 | 6300 | 9375 | 398 | |
3 | 350 | 851 | 0.095 | 2.4 | 1 | 16 | 0.235 | 6.4 | 2.81 | 71.4 | 4461 | 6639 | 7030 | 10462 | 435 | |
3 | 500 | 1221 | 0.095 | 2.4 | 2/0 | 16 | 0.265 | 6.7 | 3.19 | 81.0 | 6460 | 9614 | 9525 | 14175 | 536 |
Enter Your Message