15KV 133% TS Copper Special Cables Armor X Cable XLPE Insulation
Contact Person : Andrea
Phone Number : 0086-371-60547601
whatsapp : +8613598873045
Detail Information |
|||
Conductor:: | 2 AWG Thru 500 Kcmil Coated Annealed Copper, Bunched Wires, | Insulation:: | Ethylene Propylene Rubber (EPR) Insulation, |
---|---|---|---|
Ground-Check Conductor: | Coated Copper, Specially Stranded To Provide Extensibility Without Sustaining Tensile Load, Thereby Providing Maximum Resistance To Flex Fatigue • Insulated With High-strength Polypropylene And Placed In The Center Interstice | Grounding Conductors:: | Three Coated Copper |
Shield: | A Flexible Coated Copper Braid Shield Under An Aluminum Tape Provides Protection From Radiated Noise And A Low Transfer Impedance Path For The High Frequency Components Of PWM Signals | Jacket: | Reinforced, Two-layer, Extra-heavy-duty, Lead-cured Chlorinated Polyethylene (CPE) |
High Light: | copper welding cable,special power cable |
Product Description
VFD-BGC Power, Shielded Round Portable w/Extensible Ground-Check, EPR/CPE 2000 Volts, 90°C, Three Conductor power cable
Product Construction
Conductor:
• 2 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
Insulation:
• Ethylene Propylene Rubber (EPR) insulation,
Ground-Check Conductor:
• Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue
• Insulated with high-strength polypropylene and placed in the center interstice
Grounding Conductors:
• Three coated copper, rope-lay-stranded per ASTM B172
Shield:
• A flexible coated copper braid shield under an aluminum tape provides protection from radiated noise and a low transfer impedance path for the high frequency components of PWM signals
Jacket:
• Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE)
Options:
• Colored jackets are available
• Anamaxx® jacket
Applications:
• Designed for use as a trailing cable on AC mining equipment:
- From the inverter to the motor on variable frequency drive (PWM) systems
- Where radiated EMI is causing interference with nearby systems
- Where a ground-check conductor is required for fail-safe ground monitoring
- With wireless ground monitoring systems
Features:
• Flexible overall shield provides shock hazard protection
• Symmetrical grounding system does not produce induced voltages when operating in a balanced three-phase system and minimizes common mode current in PWM drive systems
• Enhanced ground-check conductor has longer flex life and durability
• Excellent heat, moisture, steam, oil, chemical and radiation resistance
Features (cont’d):
• Flexible for easy handling
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures
Compliances:
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection
Packaging:
• Material cut to length and shipped on non-returnable reels